摘要 目的:为了顺利解决F52-8C程控X线机程序提示灯丝增温异常的故障。方法:通过对F52-8C程序检测灯丝增温异常的原理分析,结合长期对该故障的跟踪维修,总结设计对此故障的维修解决方案,为类似故障维修工作提供参考和依据。结果:成功设计了F52-8C程控X线机灯丝增温异常的故障解决方案。结论:该解决方案设计经过实践检验可行性较强,方案条理清晰,既有故障维修的普遍实用性,又有对该故障较强的针对性。 Objective: For the sake of smooth solution fault of filament warming up abnormity of F52-8C procedure controls X-ray machine.Methods: By the principle analysis to the F52-8C procedure examination filament warming up abnormity,we combine long-term to the break down of follow maintain,tally up to design solution for the breakdown,for similar of the breakdown maintain a work to provide reference and basis.Results: Succeeded to design F52-8C breakdown solution of filament warm up abnormity.Conclusions: The solution designs feasibility is stronger after practice,and the project logical arrangement is clear.So the solution is universal function for the breaddown maintains,and then stronger of pertinency.
作者 何乐民 曹允希 韩丰谈 HE Le-min,CAO Yun-xi,HAN Feng-tan(Radiology Department,Taishan College of Medical Science,Taian Shandong 271016,China)
出处 《中国医学物理学杂志》 CSCD 2011年第4期 2781-2783,共3页 Chinese Journal of Medical Physics
关键词 程控X线机 灯丝增温异常 方案设计 programmable X-ray equipment filament warm up abnormity project designs