期刊文献+

TR—FIA与RIA法检测HBV标志物的比较分析 预览 被引量:1

A Contrast Study of Time-resolved Fluoroimmunoassay and RIA about HBV Marker
在线阅读 下载PDF
分享 导出
摘要 铕(Eu)标记时间分辨荧光免疫技术(TR-FIA)是新近推出的一种非放射性标记微量检测技术, 将其与RIA比较分析, 结果表明: TR-FIA法较RIA法灵敏度高, 测量范围宽, 准确度相近; 在乙型肝炎病毒标志物(HBV M)常见的8种组合模式中, 有7种完全符合(符合率为100%),只有HBSAg+抗-Hbe+抗-HBc组合模式符合率为73.3%,而HBeAg值差异较大. To inquire into the value of clinical practice of time-resolved fluoroimmunoassay(TRFIR) of Eu marking about HBV marker, the method of TRFIR against the method of RIA were checked.The result showed that the sensitivity and measuring scope of TR FIA is separately higher and wider than them of RIA and the accuracy is close by.In 8 common modes of HBV marker, seven of them were complete the same.Only the coincidence ratio of anti-HBe+anti-HBc+HBsAg combinatorial mode was 73.3 percents.But the data of HBeAg were different.
作者 张新利 谭玉华 党淑萍 ZHANG Xin-li, TAN Yu-hua, DANG Shu-ping (Ridiommunoassay Centre, Shanxi People′s Hospital, Xi′an, China)
出处 《标记免疫分析与临床》 CAS 2004年第4期 222-224,共3页 Labeled Immunoassays and Clinical Medicine
关键词 时间分辨荧光免疫分析 放射免疫分析 肝炎病毒 乙型 Eu Time-resolved fluoroimmunoassay(TRFIR) RIA HBV