改进重铬酸钾法快速测定水样CODcr 预览 被引量:8

Rapid determination of COD in water sample by using potassium dichromate
在线阅读 下载PDF
收藏 分享 导出
摘要 研究了用硫酸锰代替贵金属硫酸银作催化剂,在H2SO4-H3PO4介质中,重铬酸钾回流法测定水样中CODcr的新方法。通过实验,确定了最佳测定条件:MnSO4浓度为1×10^-2mol.L^-1;混酸溶液(H2SO4:H3PO4)=5:1(体积比);回流时间10min。并与标准方法进行了对比,准确度和精密度同标准法相近,大大节约了分析时间。 A newanalytical method of the chemical oxygen demand (COD) for water sample is developed. The manganese sulfate substitutes the silver sulfate for the catalyst with the H2SO4-H3PO4 instead of H2SO4. The results show that the optimal condition is the 1×10^-1 mol. L^-1 of manganese sulfate with the ratio of H2SO4 to H3PO4 = 5:1 and 10-minutes of the condensation time. It is compared with the standard model and the analytical time is greatly reduced with almost the same accuracy and precision.
作者 杨迎春 张丽 叶晓东 YANG Ying-chun, ZHANG LI, YE Xiao-dong (Dept. of Environmental Engineering, CULT, Chengdu 610225, China)
出处 《成都信息工程学院学报》 2006年第2期 273-276,共4页 Journal of Chengdu University of Information Technology
基金 四川省科技厅应用基础(GY029-010-02) 成都信息工程学院科技发展基金资助(CSRF200402)
关键词 化学需氧量(CODcr) 重铬酸钾法 MNSO4 chemical oxygen demand potassium dichromate manganese sulfate