摘要 目的分析CT血管成像(CTA)在脑动脉瘤诊断中漏诊的原因,进一步提高头部CTA的检查和诊断能力。方法搜集同时行CTA和DSA检查的脑动脉瘤患者病例资料36例,DSA用Philips-HM3000数字减影机,CT用GE Light-speed及Philips Brilliance16层CT机进行扫描,层厚0.625-1.250mm。在工作站上进行脑血管后处理重组,诊断结果与DSA相对比。结果经DSA证实的36例脑动脉瘤,初次CTA诊断明确32例,漏诊4例。对照DSA回顾性分析,再次行VR重组,CTA又找到动脉瘤2例,而4例瘤体直径均小于3mm。结论头部CTA诊断脑动脉瘤仍存在一定的局限性,合理的扫描方法和细致的观察有助于减少漏诊,提高诊断的准确性。 Objective:To analyse the reason of missing of cerebral aneurysm and further improve the ability of examination and diagnosis in head computed tomography angiography (CTA). Methods: Thirty-six patients with cerebral aneurysms were examined with CTA and DSA. Reconstruction images were processed at the workstation. We compared the CTA results with those of DSA. Results: Among thirty-six cases, two aneurysms were not displayed in CTA,which were demonstrated in DSA. Two aneurysms were missing, which were demonstrated after the review of reconstruction. All these four aneurysms were less than 3mm in diameter. Conclusion:There are still certain limitations in the diagnosis of cerebral aneurysm by head CTA. Reasonable scanning and careful observation are helpful to avoid the missing of lesions and improve the diagnostic accuracy.
作者 宁殿秀 李智勇 王克礼 苗延巍 伍建林 郎志谨 杜敏安 NING Dian-xiu. LI Zhi- yong. WANG Ke-li, et al.( Department of Radiology, the First Affiliated Hospital of Dalian Medical University, Niaoling 116011 ,P. R. China)
出处 《放射学实践》 2007年第4期 365-367,共3页 Radiologic Practice
基金 辽宁省教育厅科学研究计划资助(05L097)
关键词 颅内动脉瘤 体层摄影术 X线计算机 脑血管造影术 CT血管成像 Intracranial aneurysm Tomography, X-ray computed Cerebral angiography Computed tomography angiography
作者简介 宁殿秀(1960-),男.辽宁大连人,硕士.主任技师,主要从事CT血管造影技术工作。
  • 相关文献

参考文献7

  • 1宁殿秀,李智勇,王秀凤,苗延巍,伍建林,郎志谨.MSCTA在脑血管性疾病诊断中的应用价值[J].医学影像学杂志,2004,14(4):269-271. 被引量:17
  • 2宁殿秀,王克礼,李智勇,苗延巍,伍建林,郎志谨.MSCTA在四肢血管疾病中的临床应用[J].放射学实践,2005,20(2):177-179. 被引量:7
  • 3Villablanca JP,Jahan R,Hooshi P,et al.Detection and Characterization of Very Small Cerebral Aneurysms by Using 2D and 3D Helical CT Angiography[J].AJNR,2002,23(7):1187-1198. 被引量:1
  • 4Bae KT,Heiken JP,Brink JA.Aortic and Hepatic Contrast Medium Enhancement at CT:Part Ⅰ Prediction with a Computer Model[J].Radiology,1998,207(3):647-655. 被引量:1
  • 5Prokesch RW,Coulam CH,Chow LC,et al.CT Angiography of the Subclavian Artery:Utility of Curved Planar Reformations[J].J Comput Assist Tomogr,2002,26(2):199-201. 被引量:1
  • 6Raman R,Napel S,Rubin GD.Curved-slab Maximum Intensity Projection:Method and Evaluation[J].Radiology,2003,229 (1):255-260. 被引量:1
  • 7Lawler LP,Fishman EK.Multi-detector Row CT of Thoracic Disease with Emphasis on 3D Volume Rendering and CT Angiography[J].RadioGraphics,2001,21(5):1257-1273. 被引量:1

二级参考文献11

共引文献21