期刊文献+

导线污秽对高压直流输电线路电晕特性的影响 预览 被引量:31

Influence of Contaminations of the Conductor on HVDC Transmission Line Corona Characteristics
在线阅读 下载PDF
收藏 分享 导出
摘要 高压直流架空线路导线表面附着的污秽物质会影响线路的电晕特性,而目前我国采用的线路电晕对环境影响的经验公式只考虑了导线表面场强和线路结构,为此利用1.6 m×1.6 m小电晕笼进行直流线路导线涂污实验,导线外径2.4 cm,使用3种成分的状态的干燥涂污。实验结果表明,在±500 kV高压直流线路表面场强附近,污秽物质使得离子电流和正极性导线可听噪声显著增加。导线电晕特性与污秽物质的成分密切相关,且有明显的极性效应。结合电晕图像和电晕脉冲测量数据,解释了涂污导线电晕特性变化的原因,并对下一阶段的研究工作予以展望。 The contaminations adhering to the surface of HVDC overhead transmission line affect the conductor corona characteristics.The artificial pollution experiments of DC transmission line were carried out in a small corona cage,and experimental parameters were selected in the second section.The experimental results reveal that the contaminations on the conductor surface can increase the ion current and the audible noise of positive polarity conductor obviously under the electric field of HVDC 500 kV transmission line.Corona characteristics change with different contaminations' components,and the polarity effect is obvious.Factors that affect the corona characteristics of contaminated conductor are illustrated combined with corona photographs and measurement datum of the corona pulse.The next-phase research is introduced in the last section.
作者 赵宇明 麻敏华 关志成 惠建峰 王黎明 李秋玮 ZHAO Yu-ming;MA Min-hua;GUAN Zhi-cheng;HUI Jian-feng;WANG Li-ming;LI Qiu-wei(Graduate School of Shenzhen;Tsinghua University;Shenzhen 518055;China)
出处 《高电压技术》 EI CAS CSCD 北大核心 2007年第12期 49-54,共6页 High Voltage Engineering
基金 国家自然科学基金(90210030).
关键词 导线电晕 高压直流输电 污秽 可听噪声 离子电流 电晕损耗 conductor corona HVDC contaminations audible noise ion current corona loss
作者简介 赵宇明1978-,男,博士,助研,主要研究输电线路电磁环境问题。电话:(0755)83618753;E-mail:zym97@mails.tsinghua.du.cn 麻敏华1982-,女,硕士,主要研究输电线路电磁环境问题。 关志成1944-,男,博士,教授,主要研究电力系统外绝缘问题。 惠建峰1979-,男,博士,主要研究气体放电及电力系统外绝缘问题。
  • 相关文献

参考文献16

二级参考文献53

共引文献422

同被引文献422

引证文献31

二级引证文献208

投稿分析

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部 意见反馈