期刊文献+

常规工况下多弯头数脉动热管运行性能的实验研究 预览 被引量:4

Experimental Study of the Operation Performance of Multi-elbow Pulsating Heat Pipes at Conventional Operating Conditions
在线阅读 下载PDF
收藏 分享 导出
摘要 设计了两组内径1和2mm的40个弯头细铜管组成的脉动热管,通过开启或关闭管路中的一个阀门,可以得到闭式或开式两种回路形式,分别采用R123、水及酒精为工作介质,充液率从15%变化至95%,安装角度可任意调节。通过实验,分析比较了管内径、工质种类及充液率、加热角度以及回路形式等多弯头数脉动热管在常规工况下启动及传热性能的影响。 Two groups of pulsating heat pipes consisting of 40 thin copper tube elbows with an inner diameter of 1 and 2 mm respec-tively were designed. Two loop types,closed or open,can be made available by opening or closing a valve in the pipe. With R123,water and alcohol serving as working media respectively,liquid filling rate ranges from 15% to 95% and the installation angle can be regulated freely. Through tests,analyzed and compared was the influence of the inner diameter,working medium,liquid filling rate,heating angle and loop type of the multi-elbow pulsating heat pipe on its startup and heat transfer performance at conventional operating conditions.
作者 杨洪海 万勍 韩洪达 YANG Hong-hai,WAN Qing,HAN Hong-da (College of Environment Science and Engineering,Donghua University,Shanghai,China,201620)
出处 《热能动力工程》 CAS CSCD 北大核心 2009年第1期 77-80,共4页 Journal of Engineering for Thermal Energy and Power
基金 上海市重点学科建设基金资助项目(B604)
关键词 脉动热管 弯头数 回路形式 运行性能 影响因素 pulsating heat pipe,number of elbows,loop type,operation performance,influencing factor
作者简介 杨洪海(1968-),女,浙江上虞人,东华大学副教授.
  • 相关文献

参考文献10

二级参考文献69

共引文献63

同被引文献71

引证文献4

二级引证文献8

投稿分析

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部 意见反馈
新型冠状病毒肺炎防控与诊疗专栏