摘要 目的:验证SPECT均匀性的响应与核素的能量无关。方法:利用GE公司提供的NEMA软件进行测试,对不同点源静态采集40000K计数,各点源采集10次。结果:直观比较所得图像,图像的均匀性良好,三种点源的图像其密度无差异。对点源^57Co、99mTc、^131I分别重复测试10次所得的数据显示,其均匀性良好,经方差分析F检验三种不同点源所测得微分均匀性(DU)无显著差异别;积分均匀性(IU)无显著差 : Purpose: To explore the effect of radionuclides with different energy on testing SPECT inherent uniformity.Method: We used three different point sources--57Co,99mTc,131I to test the inherent uniformity ,and each was acquired 10 times with 40,000 K counts.Results:The differential uniformities of UFOV detected for 57Co, 99mTc,131I had no significant difference The differential uniformities of CFOV had also no significant difference. Conclusion: There is no difference in testing the SPECT inherent uniformity with the radionuclides of different energy.