期刊文献+

碘对比剂CT增强扫描临床应用的方案设计、科学规范与风险防范 预览 被引量:1

The project design,scientific normalization and risk precaution in clinical application of iodinatedcontrast medium enhanced CT scanning
在线阅读 免费下载
收藏 分享 导出
摘要 随着我国高端CT设备拥有量持续快速增加,CT新成像技术的临床应用,接受CT增强扫描患者数量激增,因而碘对比剂的使用量大幅增加。掌握碘对比剂药代动力学、成像设备的属性,建立和遵循碘对比剂使用标准和操作规程十分必要,能在有助于确保获得最佳增强效果的同时保证安全,达到患者真正受益的目的。 With continuous fast growth in possessing capacity of high-end CT equipment in China and the clinical application of new CT imaging techniques,in recent years has been seen a tremendous increase in the number of enhanced CT scan as well as the use of iodinated contrast medium. Imaging physicians really need to understand the pharmaeokinetics of iodinated contrast medium and the properties of imaging equipment,to set up and follow a standard operating procedure for using iodinated contrast medium,thus just can make sure to get the best contrast efficacy mean while assuring safety,and let the patients being truely benefit.
作者 王宝华 韩兵 WANG Bao-hua,HAN Bing. (The Qingdao Second Sanatorium of Jinan Military Region, Qingdao,Shandong 266071,China)
出处 《实用医药杂志》 2015年第8期710-713,共4页 Practical Journal of Medicine & Pharmacy
关键词 碘对比剂 体层摄影术 X线计算机断层扫描 Iodinated contrast medium Radiography X.ray Computed Tomography
  • 相关文献

参考文献31

  • 1碘对比剂使用指南(第2版)[J].中华放射学杂志,2013,47(10):869-872. 被引量:78
  • 2无.对比剂使用指南(第1版)[J].中华放射学杂志,2008,42(3):320-325. 被引量:54
  • 3van der Molen AJ,Thomsen HS,Morcos SK.Effect of iodinated contrast media on thyroid function in adults[J].Eur Radiol,2004,14(5):902-907. 被引量:1
  • 4Thomsen HS.European Society of Urogenital Radiology(ESUR)guidelines on the safe use of iodinated contrast media[J].Eur J Radiol,2006,60(3):307-313. 被引量:1
  • 5Widmark JM.Imaging-related medications:a class overview[J].Proc(Bayl Univ Med Cent),2007,20(5):408-417. 被引量:1
  • 6JSN,JRS,and JCS Joint Working Group.Guidelines on the use of iodinated contrast media in patients with kidney diease 2012:digest version[J].Circ J,2013,77(6):1883-1914. 被引量:1
  • 7Kondo H,Kanematsu M,Goshima S,et al.Body size indexes for optimizing iodine dose for aortic and hepatic enhancement at multidetector CT:comparison of total body weight,lean body weight,and blood volum[J].Radiology,2010,254(1):163-169. 被引量:1
  • 8Ho LM,Nelson RC,Delong DM.Determining contrast medium dose and rate on basis of lean body weight:dose this strategy improve patient-to-patient uniformity of hepatic enhancement during multi-detector row CT?[J].Radiology,2007,243(2):431-437. 被引量:1
  • 9Nakaura T,Kidoh M,Sakaino N,et al.Low contrast-and low radiation dose protocol for cardiac CT:of thin adults at 256-row CT:usefulness of low tube voltage scans and the hybrid iterative reconstruction algorithm[J].Int J Cardiovase Imaging,2013,29(4):913-923. 被引量:1
  • 10心脏冠状动脉多排CT临床应用专家共识[J].中华放射学杂志,2011,45(1):9-17. 被引量:153

二级参考文献254

共引文献438

同被引文献15

引证文献1

二级引证文献7

投稿分析
职称考试

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部 意见反馈