摘要 研究了TTA和BTA按GB/T 14422-2008《锅炉用水和冷却水分析方法苯骈三氮唑的测定》方法测定结果的准确度,考查了TTA和BTA抗游离氯的稳定性及游离氯对TTA和BTA铜缓蚀性能的影响。试验表明:通过GB/T 14422-2008所述方法的测定结果具有较高的精密度和准确度;随着游离氯浓度的提高,TTA和BTA分解率均会不断上升,BTA比TTA具有更好的抗氯性;游离氯的存在会影响TTA和BTA的铜缓蚀性能。 The testing accuracy of TTA and BTA based on GB/T 14422-2008 "Analysis of water used in boiler and cooling system;determination of benzotrazole" was studied. The stability of TTA and BTA to free chlorine was investigated as well as effect of free chlorine on TTA and BTA copper corrosion inhibiting performance. The result indicates that the final testing result of TTA and BTA based on GB/T 14422-2008 has higher precision and accuracy. With increasing of free chlorine concentration, the decomposition rates of TTA and BTA will increase.BTA shows better chlorine resistant performance than TTA. Therefore,the existence of free chlorine can affect copper corrosion performance of TTA and BTA.
作者 孙晓丹 喻果 程晓婷 SUNXiao-dan, YU Guo, CHENXiao-ting (Weihai Xiangyu Technology Co.,Ltd., Shandong Weihai 264200, China)
出处 《当代化工》 CAS 2015年第8期1800-1802,共3页 Contemporary Chemical Industry
关键词 游离氯 甲基苯骈三氮唑TTA 苯骈三氮唑BTA Free chlorine TTA BTA
作者简介 孙晓丹(1987-),女,黑龙江双鸭山人,工程师,主要从事水处理剂的研究、应用及水处理技术服务工作。E-mai1282887321@qq.com
  • 相关文献

参考文献5

  • 1徐群杰,周国定.不同pH条件下几种铜缓蚀剂的比较研究[J].腐蚀与防护,1999,20(4):160-161. 被引量:9
  • 2Sohn S,Kang T.The effects of tin and nickel on the corrosion behavior of 60Cu-40Zn alloys[J].Journal of Alloys and Compounds,2002,335(1-2): 281-289. 被引量:1
  • 3周本省编著..工业冷却水系统中金属的腐蚀与防护[M].北京:化学工业出版社,1993:284.
  • 4中华人民共和国国家质量监督检验检疫总局/中国国家标准化委员会.GB/T14422-2008《锅炉用水和冷却水分析方法苯骈三氮唑的测定》[s].北京:中国标准出版社出版,2008. 被引量:1
  • 5中华人民共和国国家质量监督检验检疫总局.GB/T18175-2000《水处理剂缓蚀性能的测定一旋转挂片法》[s].北京:中国标准出版社出版,2000. 被引量:1