期刊文献+

X射线CT成像检测方法对复合材料内部分层缺陷检测结果的影响研究 预览

INFLUENCE OF X-RAY CT IMAGING DETECTION METHOD ON TESTING RESULTS OF DELAMINATION DEFECTS IN COMPOSITE MATERIAL
在线阅读 下载PDF
分享 导出
摘要 采用X射线断层CT成像检测、X射线螺旋CT成像检测和X射线锥束CT成像检测三种X射线CT成像检测方法对预制机械加工模拟分层缺陷的碳纤维树脂基复合材料进行检测,从检测速度、检测图像质量、缺陷分辨率三个方面比较这三种X射线CT成像检测方法。结果表明,X射线锥束CT成像检测方法在对复合材料内部分层缺陷的检测中具有检测效率最高,检测图像质量最好以及缺陷尺寸测量误差最小的优点,为复合材料内部其他缺陷检测方法的选择提供借鉴意义。 Three kinds of X-ray CT imaging detection methods including X-ray tomography CT imaging detection method,X-ray spiral CT imaging detection method and X-ray cone beam CT imaging detection method were used to detect carbon fiber matrix composites with prefabricated mechanical processing simulated delamination defects. These X-ray CT imaging detection methods are compared from three aspects,i.e.,detection speed,image quality and defect resolution. The results show that the detection method of X-ray cone beam CT imaging has the highest detection efficiency,the best image quality and the smallest defect size measurement error in the detection of delamination defects in composite materials. It provides a reference for the selection of other defects in composite materials.
作者 董方旭 王从科 凡丽梅 赵付宝 张霞 郑素萍 DONG Fang-xu;WANG Cong-ke;FAN Li-mei;ZHAO Fu-bao(CNGC Institute 53,Jinan 250031,China)
出处 《玻璃钢/复合材料》 CAS 北大核心 2019年第3期86-91,共6页 Fiber Reinforced Plastics/Composites
关键词 X射线CT成像检测 复合材料 检测方法选择 X-ray CT imaging detection composite material selection of detection methods
作者简介 董方旭(1990-),男,硕士,工程师,主要从事复合材料X射线无损检测技术方面的研究,727061825@qq.com。
  • 相关文献

参考文献12

二级参考文献128

共引文献107

投稿分析

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部 意见反馈