胸部能谱成像与常规CT扫描辐射剂量与图像质量对比研究 预览 被引量:2

Comparative study on radiation dose and image quality between spectral imaging & conventional CT plain in thorax
在线阅读 下载PDF
分享 导出
摘要 目的:探究胸部能谱成像与常规胸部CT扫描的辐射剂量及图像质量有无差异。方法:前瞻性对33例因临床诊断及疑诊肺癌的成年患者行胸部CT平扫与增强,增强时用能谱成像扫描,平扫及增强均通过胸部不同平面的脂肪组织、肌肉组织进行客观评价图像噪声、主观评分,并记录辐射剂量。采用独立样本T检验比较二者扫描方式的辐射剂量、不同平面70 kev单能量图像与常规扫描混合能量客观指标及主观评分。结果:能谱扫描和常规扫描的CT剂量指数、有效剂量差异无统计意义(P〉0.05)。能谱扫描70 kev单能量的三个不同平面水平的脂肪组织、肌肉组织噪声及图像质量的主观评分对应常规混合能量扫描差异均无统计学意义(P〉0.05)。结论:胸部CT能谱扫描与常规扫描的射线剂量相当;70 ke V单能量图像的噪声低于常规扫描的FBP重建图像,可在临床中常规开展应用。 Objective: To explore the difference between the radiation dose and image quality of chest spectral CT imaging and conventional chest CT scan.Methods: 33 adult patients diagnosed or suspected with primary bronchogenic carcinoma prospectively underwent non-enhanced CT scan and post-contrast CT scan with spectral imaging scanner.Both types of the scan evaluated the noise objectively,then scored them subjectively through adipose tissue as well as musculature on various levels of the chest.The radiation doses were recorded at the same time.The radiation doses of both types of scans were compared by independent samples T-test,which was also used to compare the objective measures and subjective scores between the 70 kev-monochromatic energy image and mix-energy routine scan.Results: There was no significant difference in the CT dose index and the effective dose between the spectral scanning and conventional scanning(P〈0.05).There was also no significant difference of image of noise and image quality for the adipose tissue and musculature among the three groups with different levels of 70 kev-monochromatic energy image and mix-energy routine scan(P〈0.05).Conclusion: Firstly,radiation doses of spectral chest CT is correspondent to routine CT.Secondly,the noise of 70 ke V monochromatic energy imaging is lower than that of routine scanning FBP reconstructed images,which means it can be routinely conducted in clinic.
作者 徐秋贞 朱海雪 吕燕 邵海磊 陈晓晖 居胜红 XUQiu-zhen, ZHUHai-xue, LVYan, SHAO Hai-lei, CHENXiao-hui, JUSheng-hong(Department of Radiology,Zhongda Hospital Ajfiliated to Southeast University,Nanjing 210009,China)
出处 《东南大学学报:医学版》 北大核心 2017年第5期837-840,共4页 Journal of Southeast Univ: Medical Sci Ed
关键词 能谱成像 常规CT 辐射剂量 图像质量. spectral imaging routine CT radiation dose image quality
作者简介 徐秋贞(1968-),女,湖北浠水人,医学硕士,副教授,副主任医师,研究方向:胸、腹部影像诊断,E-mail:xqiuZhen831@sina.com.
  • 相关文献

参考文献4

二级参考文献46

  • 1梁长虹,黄飚.多层CT技术飞速发展,临床应用不断创新[J].中华放射学杂志,2006,40(9):901-902. 被引量:31
  • 2Yamada Y,Jinzaki M,Tanami Y. Virtual monochromatic spectral imaging for the evaluation of hypovascular hepatic metastases:the optimal monochromatic level with fast kilovoltage switching dual-energy computed tomography[J].Investigative Radiology,2012.292-298. 被引量:1
  • 3Qian LJ,Zhu J,Zhuang ZG. Differentiation of neoplastic from bland macroscopic portal vein thrombi using dual-energy spectral CT imaging:a pilot study[J].European Journal of Radiology,2012.2178-2185. 被引量:1
  • 4Lin XZ,Wu ZY,Tao R. Dual-energy spectral CT imaging of insulinoma-value in preoperative diagnosis compared with conventional multi-detector CT[J].European Journal of Radiology,2012.2487-2494. 被引量:1
  • 5Kaza RK,Caoili EM,Cohan RH. Distinguishing enhancing from nonenhancing renal lesions with fast kilovoltage-switching dual-energy CT[J].American Journal of Roentgenology,2011.1375-1381. 被引量:1
  • 6Lv P,Lin XZ,Li J. Differentiation of small hepatic hemangioma from small hepatocelhlar carcinoma:recently introduced spectral CT method[J].Radiology,2011.720-729. 被引量:1
  • 7Silva AC,Morse BG,Hara AK. Dual-energy (speetral) CT:applications in abdominal imaging[J].Radiographics:A Review Publication of the Radiological Society of North America,Inc,2011.1031-1046. 被引量:1
  • 8Li B,Yadava G,Hsieh J. Quantification of head and body CTDIvol of dual-energy X-ray CT with fast-kVp switching[J].Medical Physics,2011.2595-2601. 被引量:1
  • 9Zhang D,Li X,Liu B. Objective characterization of GE discovery CT750 HD scanner:gemstone spectral imaging mode[J].Medical Physics,2011.1178-1188. 被引量:1
  • 10Leng S,Yu L,Wang J. Noise reduction in spectral CT:reducing dose and breaking the trade-off between image noise and energy bin selection[J].Medical Physics,2011.4946-4957. 被引量:1

共引文献31

同被引文献16

引证文献2

投稿分析

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部 意见反馈