期刊文献+

基于电站监测系统时间尺度冗余性的数据协调方法 预览

Data Reconciliation Method for Monitoring System of Power Unit on Basis of Redundancy Information on Time Scale
在线阅读 下载PDF
收藏 分享 导出
摘要 电站性能监控与运行优化离不开可靠的在线监测系统,而监测系统的可靠性依赖于传感器的布置,精度以及冗余性等。以某电站660 MW机组汽机侧监测系统为研究对象,采用改进的数据协调方法分析了该电站监测系统中传感器的布置与冗余度等问题。通过在传统数据协调算法中加入时间尺度上的冗余信息增加了测量系统的可靠性。最后通过模拟传感器故障案例,分析了改进的数据协调方法应用与汽机监测系统的可行性与可靠性。结果表明将改进的数据协调方法应用于电站汽机侧监控系统可有效协调循环水流量测点的准确性。同时在传感器故障分析案例中,有效排查出实发功率传感器的模拟故障。 The performance monitoring and the optimal operation of the power unit highly rely on the reliable online monitoring system which involves the arrangement,accuracy and redundancy of the sensors. With the application of enhanced data reconciliation method,the redundancy information on time scale was considered for improving the monitoring result. A case study of a 660 MW power unit was given for analyzing the arrangement and the accuracy of the sensors and especially for analyzing the redundancy information,where a simulation case of the sensor fault of mass flowrate was also applied. The case study showed that with the application of enhanced data reconciliation method to the turbine system,the accuracy of the mass flowrate were well increased. Meanwhile,the enhanced data reconciliation method successfully detected the simulated sensor failure of power output.
作者 杨勇平 李晓恩 王宁玲 魏庆 杨志平 YANG Yongping, LI Xiaoen, WANG Ningling, WEI Qing, YANG Zhiping(National Thermal Power Engineering and Technology Research Center, North China Electric Power University,Beijing 102206, China)
出处 《华北电力大学学报:自然科学版》 北大核心 2018年第3期67-73,80共8页 Journal of North China Electric Power University
基金 国家自然科学基金资助项目(U1261210,51306050) 国家重点基础研究发展计划(973计划)项目(2015CB251505) 中央高校基本科研业务费专项资金资助项目(2015MS43)
关键词 监测系统 数据协调 传感器 汽机系统 冗余度 时间尺度 monitoring system data reconciliation sensor turbine system redundancy time scale
  • 相关文献

参考文献7

二级参考文献47

共引文献12

投稿分析
职称考试

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部 意见反馈