期刊文献+

火电机组电气和热工保护不正常动作隐患排查及治理措施 预览

Hidden Trouble Investigation and Governance Measures of Electricaland Thermotechnical Protection Malfunction of Thermal Power Unit
在线阅读 下载PDF
分享 导出
摘要 电气热工保护稳定运行、可靠正确动作,是影响机组及电网安全和可靠性的重要因素。通过对三大类火电机组典型电气、热工保护不正常动作导致机组非停和存在非停隐患的案例进行总结分析,重点提出机组投运后发电厂如何进行隐患排查,并提出切实有效的改善措施,从而大大提高了电气热工保护稳定性和可靠性,避免出现保护不正常动作而导致的不安全事件或事故。 The stable operation, reliable and correct action of electricaland thermotechnical protection is an important factor affecting the safety and reliability of the unit and the power unit. This paper summarizes and analyzes the unplanned outage and existence of unplanned outage hidden danger of the unit by the abnormal action of the typical electricaland thermotechnical protection of three types of thermal power units. In order to improve the stability and reliability of protection and avoid unsafe events or accidents, How to carry out the hidden trouble investigation and put forward effective measures is very important.
作者 张仲琪 ZHANG Zhong-qi (Shanxi Luneng Hequ Power Generation Co., Ltd., Xinzhou 036500, China)
出处 《通信电源技术》 2018年第4期251-253,256共4页 Telecom Power Technologies
关键词 火电机组 电气热工保护 不正常动作 机组非停 thermal power unit electricaland thermotechnical protection malfunction unplanned outage
作者简介 张仲琪(1980-),男,内蒙古宁城人,本科,中级工程师。主要研究方向为发电厂生产管理。