基于卷积反投影的CT系统参数标定和成像模型 预览

CT System Parameters Calibration and Imaging Model Based on Convolution Back - Projection
在线阅读 下载PDF
收藏 分享 导出
摘要 该文考察了电子计算机断层扫描 (CT )系统的参数标定和未知样品的成像问题。基于标定模板的接收信息,建立了多个优化模型,并求解得到了模板的旋转角度、探测器间距和旋转中心,从而解决了CT系统的参数标定问题;采用傅立叶变换和卷积反投影法建立了介质吸收率重建模型,根据CT系统对X射线接收信息的数值,并结合已标定的参数,采用MATLAB编程求解,得到了未知介质的吸收率、形状和位置,解决了CT系统的参数标定和成像问题。 This article investigated the parametric calibration of computed tomography (CT )systems and the imaging of unknown samples.Based on the received information of the calibration template,a number of optimization models were established,and the rotation angle,distance between detectors,and rotation center of the template were solved.The parameter calibration of the CT system was solved.The Fourier transform and filtered back projection method were used to establish the calibration parameters.The medium absorption rate reconstruction model was based on the value of the X-ray receiving information of the CT system,combined with the calibrated parameters,and solved by MATLAB programming.The absorption rate,shape and position of the unknown medium were obtained,and the parameter calibration and imaging of the CT system were solved.
作者 王誉儒 杨玉聪 官庄 王志勇 WANG Yuru 1,YANG Yucong 1,GUAN Zhuang 1,WANG Zhiyong 2(1.Yingcai Honors College,University of Electronic Science and Technology of China,Chengdu 611731,China;2.School of Mathematical Science,University of Electronic Science and Technology of China,Chengdu 611731,China)
出处 《实验科学与技术》 2018年第5期11-15,共5页 Experiment Science & Technology
基金 国家自然科学基金(11301058) 中央高校基本业务费(ZYGX2015J103).
关键词 CT系统 参数标定 卷积反投影 优化模型 傅立叶变换 CT system parametric calibration filtered back projection optimization models Fourier transform
作者简介 王誉儒(1997-),男,本科生,电子科学与技术专业。;通信作者:王志勇(1980-),男,博士,副教授,主要从事随机微分方程数值解面的研究。E—mail:zhywang@ueste.edu.cn
  • 相关文献

参考文献6

二级参考文献39

  • 1《耳鼻喉科学》编写组.鼻科学[M].上海:上海人民出版社,1977.48-268. 被引量:3
  • 2[1]Budinger TF. PET instrumentation: what are the limits?[J]. Semin Nucl Med,1998,28:247-267. 被引量:1
  • 3[2]Townsend DW, Beyer T, Kinahan PE, et al. The SMART scanner: a combined PET/C T tomograph for clinical oncology[J]. IEEE Nucl Sci Symp Med Imaging Conf Rec,1998,2:1170-1174. 被引量:1
  • 4[3]Beyer T, Townsend DW, Brun T, et al. A combined PET/CT scann er for clinical oncology[J]. Nucl Med, 2000,41:1369-1379. 被引量:1
  • 5[4]Beyer T, Watson CC, Meltzer CC. A premium dual modality PET/ CT tomograph for clinical oncology[J].Electromedica, 2001,2:120-126. 被引量:1
  • 6[5]Kinahan PE, Townsend DW, Beyer T, Attenuation correction for a combined 3D PET/CT scanner[J]. Med Phys,1998,25:2046-2053. 被引量:1
  • 7[6]Riddell C, Carson RE, Carrasquillo JA, et al. Noise reductio n in oncology FD G PET images by iterative reconstruction: a quantitative assessment[J]. Nu cl Med,2001,42:1316-1323. 被引量:1
  • 8[7]Miller TR, Wallis JW. Fast maximum-likelihood reconstructio n[J]. Nucl Med,1992,33:1710-1711. 被引量:1
  • 9[8]Hudson HM, Larkin RS. Accelerated image reconstruction using ordered subsets of projection data[J].IEEE Trans Med Imaging,1994,13:601-609. 被引量:1
  • 10[9]Boellaard R, Van Lingen A, Lammertsma AA. Experimental and c linical evaluati on of iterative reconstruction (OSEM) in dynamic PET: quantitative characteristi cs and effects on kinetic modeling[J]. Nucl Med, 2001,42:808-817. 被引量:1

共引文献140

投稿分析

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部 意见反馈