PPK动态后处理测量技术及精度分析 预览

Application and Accuracy Analysis of PPK Measurement Technology
在线阅读 下载PDF
收藏 分享 导出
摘要 PPK测量技术属于GNSS动态后处理测量技术,其外业测量时不需要在流动站和基准站之间建立实时的通讯链接,作业半径大,在流动站上进行短时间的观测即可解算出厘米级的精度,介绍了PPK测量作业模式及数据处理过程,对PPK作业的局限性、提高测量精度的方法进行了探讨,并通过实地测试分析了PPK作业过程中测量时间长度、流动站与基准站的距离等因素变化对测量精度的影响,验证了在60 km作业范围内,PPK后处理差分定位精度可达到2 cm~3 cm。 PPK measurement technology belongs to the processing technology of GNSS dynamic measurement.Its measurement does not need to set up a data communication link between base station and mobile station.And its operating radius is bigger,only 2~5 epoch can obtain centimeter level accuracy in the mobile station.This paper introduces the principle of PPK measurement,operation mode and data processing,discusses the limitations of PPK operation and the methods to improve the precision.And through the test analysis the influence of factor change on accuracy,such as the time length of PPK measurement,the length of the mobile station and base station distance and other factors.It was verified that the post-positioning differential accuracy of PPK can reach 2 cm to 3 cm within 60 km of operation.
作者 王智 曹庆磊 张洪德 胡玉祥 孟庆年 Wang Zhi;Cao Qinglei;Zhang Hongde;Hu Yuxiang;Meng Qingnian(Qingdao Surveying and Mapping Research Institute,Qingdao 266032,China;Qingdao West Coast Geomatics Center Co.,Ltd.,Qingdao 266000,China)
出处 《城市勘测》 2019年第2期97-100,共4页 Urban Geotechnical Investigation & Surveying
关键词 PPK GNSS测量 基线解算 RTK 差分定位 PPK GNSS Measurement baseline calculating RTK differential positioning
作者简介 王智(1986—),男,硕士,工程师,注册测绘师,主要从事精密工程测量、工业测量和数据处理等技术工作。