期刊文献+

PPDO线雕面部提升术在面部年轻化中的应用 预览

Application of PPDO line carving facial lifting in facial rejuvenation
在线阅读 下载PDF
收藏 分享 导出
摘要 目的探讨聚对二氧环己酮(Poly-para-dioxanone,PPDO)线雕面部提升术在患者面部年轻化中的应用价值。方法回顾性分析2015年10月至2018年7月期间于我院接受线雕面部提升术治疗的83例患者的临床资料,所有入选者均需接受PPDO线雕面部提升术治疗,统计术后并发症发生情况、满意度以及面部提升术效果。结果术后即刻,68.67%的患者出现轻中度水肿,术后24h均出现轻中度水肿,术后14d,8.43%的患者水肿仍未消退,术后21d,均得以缓解;术后24h,86.75%的患者存在说话、咀嚼疼痛明显,术后14d,2.41%咀嚼时其颞部可感知轻微疼痛感,术后28d,均得以缓解;术后即刻,43.37%的患者面部存在明显淤青,术后24h,91.57可见淤青,术后14d,16.87%可见轻度皮下淤血,术后21d,均得以缓解;术后即刻,12.05%存在轻度面部凹凸不平症状,术后14d,2.41%存在轻度面部凹凸不平症状,术后21d,均得以缓解;83例患者中,非常满意占73.49%,满意占25.30%,一般占1.20%,无不满意例数;83例患者面部提升术效果如下,优60例,良17例,中6例,优良率为92.77%。结论PPDO线雕面部提升术可促使面部组织松弛者面部年轻化,且满意度以及安全性较高,利于患者接受。 Objective To evaluate the value of polyp-dioxypyclohexanone (Poly-para-dioxanone,PPDO) line carving facial lifting in facial rejuvenation of patients.Methods The clinical data of 83 patients who underwent line carving facial lifting in our hospital from October 2015 to July 2018 were analyzed retrospectively.all the selected patients needed to be treated with PPDO line engraving facial lifting,and the occurrence of postoperative complications was counted.Satisfaction and facial lifting effect.Results 68.67% of the patients developed mild to moderate edema immediately after operation,and mild edema occurred 24 hours after operation.Moderate edema,14 days after operation,8.43% of the patients still did not subside,21 days after operation,all of them were relieved.At 24 hours after operation,86.75% of the patients spoke,and the masticatory pain was obvious.On the 14th day after operation,2.41% of the patients could feel slight pain in the temporal part of mastication,and all of them were relieved 28 days after operation.Immediately after operation,43.37% of the patients had obvious facial bruises,91.57 could be seen at 24 hours after operation,16.87% had mild subcutaneous congestion on the 14th day after operation,and all of them were relieved 21 days after operation.Immediately after operation,12.05% had mild facial uneven symptoms.On the 14th day,2.41% had mild facial uneven symptoms,and all of them were relieved 21 days after operation.Among 83 patients,very satisfactory accounted for 73.49%,satisfaction accounted for 25.30%,generally accounted for 1.20%,there were no dissatisfied cases.The effect of facial lifting in 83 patients was as follows: excellent in 60 cases,good in 17 cases and good in 6 cases.The excellent and good rate was 92.77%.Conclusion PPDO line carving facial lifting can make the face of patients with facial tissue relaxation younger,and the satisfaction and safety are high,which is beneficial to the acceptance of the patients.achieve the effect of correcting depression,and patients’satisfacti
作者 高飞 GAO Fei(Wuxi Esther plastic surgery and Beauty Hospital, Jiangsu Province, 214001, China)
出处 《中国医疗美容》 2019年第6期1-4,共4页 China medical cosmetology
关键词 面部年轻化 PPDO线 线雕面部提升术 facial rejuvenation PPDO line line carving facial lifting
  • 相关文献

参考文献10

二级参考文献69

  • 1牛永敢,黄晓元.鼻额区、鼻根部解剖-美学关系对隆鼻术的指导意义[J].中国现代手术学杂志,2005,9(5):343-345. 被引量:5
  • 2闫迎军,黄渭清,方柏荣,王晓军,乔群.从解剖学角度探讨应用锯齿线行面部提升术的可行性[J].中国美容医学,2006,15(8):900-902. 被引量:10
  • 3Sheth SD, Giugliano RP. Coronary artery stents: advances in tech- nology[J]. Hosp Pract (1995), 2014, 42(4): 83-91. 被引量:1
  • 4Gonzalo N. Maeaya C. Absorbable stent: focus on chnicaI applica- tions and benefits[J]. Vasc Health Risk Manag, 2012, 8:125 - 132. 被引量:1
  • 5Werner M, Micari A, Cioppa A, et al. Evaluation of the biodegradable peripheral Igaki-Tamai stent in the treatment of de novo lesions in the superficial femoral artery: the GAlA study[ J]. JACC Cardiovasc In- terv, 2014, 7(3) : 305 -312. 被引量:1
  • 6Kraak RP, Grundeken M J, Koch KT, et al. Bioresorbable scaffolds [or tile treatment of coronary artery disease: current status and future perspective[J].Expert Rev Med Devices, 2014, 11 (5): 467 - 480. 被引量:1
  • 7Feng Q, Jiang W, Sun K, et al. Mechanical properties and in vlvo performance of a novel sliding-lock bioabsorbable poly-p-dioxanonestent[ J ]. J Mater Sci Mater Med, 2011, 22 (10) : 2319 - 2327. 被引量:1
  • 8Liu Y, Cai D, Yang J, eta]. In vitro hemoeompatibility evaluation of poly (4-hydroxybutyrate) scaffold[J]. Int J Clin Exp Med, 2014, 7(5) :1233 - 1243. 被引量:1
  • 9Standard test method for assessment of intravascular medical device materials on partial thromboplastin time (PTT) : ASTM F2382-04 (2010 ) [ S ]. West Conshohocken : ASTM International, 2010. 被引量:1
  • 10Shen X, Su F, Dong J, et al. In vitro biocompatlbility evaluation of bioresorbable copolymers prepared from L-lactide, I, 3-trimethyiene carbonate, and glycolide for cardiovascular applications[J]. J Biomater Sci Polym Ed, 2015, 26(8) : 497 -514. 被引量:1

共引文献32

投稿分析

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部 意见反馈
新型冠状病毒肺炎防控与诊疗专栏