摘要 挥发性盐基氮具有挥发性,在食物中含量越高,就表明氨基酸被破坏的越多,是反映食物新鲜程度的重要指标。在半微量定氮法的基础上,引用全自动凯式定氮仪,对熟牛肉中的挥发性盐基氮含量进行测定,并采用重复性试验和回收率试验对该方法的可靠性进行验证,结果表明,该方法测定结果准确可靠。 Volatile salt nitrogen is volatile.The higher the content in the article,the more amino acids are destroyed.Therefore,it is an important indicator of the freshness of raw fish and meat.Beef is an important part of people’s daily food.In the market,it is often cooked beef.In order to test the freshness of cooked beef,it is necessary to determine the content of volatile salt base nitrogen in cooked beef,so the quality of cooked beef is detected..Therefore,this paper discusses and analyzes the determination of volatile salt nitrogen content in cooked beef,so as to provide some suggestions for practical activities.