三焦点衍射型人工晶状体植入术后视觉质量临床评价 预览
1
作者 彭程 周星延 +1 位作者 赵江月 张劲松 《中国医科大学学报》 CAS CSCD 北大核心 2019年第5期385-389,共5页
目的比较三焦点衍射型人工晶状体( IOL)植入术后视力、屈光状态、视觉质量及满意度。方法选取在我院植入三焦点衍射型IOL( AT LISA tri839MP, Carl ZEISS)的患者40例( 50只眼)。于术后1周、 1个月、 3个月时测试单眼裸眼远视力( UDVA)... 目的比较三焦点衍射型人工晶状体( IOL)植入术后视力、屈光状态、视觉质量及满意度。方法选取在我院植入三焦点衍射型IOL( AT LISA tri839MP, Carl ZEISS)的患者40例( 50只眼)。于术后1周、 1个月、 3个月时测试单眼裸眼远视力( UDVA)、裸眼中距离视力( UIVA)、裸眼近距离视力( UNVA)、离焦曲线、客观散射指数( OSI)、调制传递函数截止频率( MTF cutoff)、斯特列尔比( SR)、眼内散射光、高阶像差,采用主观调查问卷统计患者整体满意度、光晕发生率及脱镜率。应用重复测量的方差分析进行数据分析。结果患者术后1周、 1个月、 3个月的等效球镜均在目标度数±0.5 D范围内,与术前比较差异均有统计学意义(均P < 0.001)。术后1周、 1个月、 3个月的UDVA、 UIVA、 UNVA均有明显提高,与术前比较差异均有统计学意义(均P < 0.001),且均可到达0.3 logMAR或以上。术后3个月时,离焦曲线1.0 D ~-2.5 D范围内,视力处于较高值,均>0.2 logMAR,且变化平缓。患者术后1周、 1个月、 3个月的log[ s]与术前比较差异无统计学意义( F = 0.460, P = 0.710)。术后1周、 1个月、 3个月的OSI值较术前下降,且差异有统计学意义( F = 16.813, P < 0.001),术后1周、 1个月、 3个月的MTF cutoff、 SR值较术前增大,差异有统计学意义( F =-1.469, P < 0.001;F = 3.405, P = 0.019)。术后1周、 1个月、 3个月的球差较术前下降,且差异有统计学意义( F = 18.913, P < 0.001);术后各时间点的高阶像差、慧差、三叶草差、与术前比较,差异均无统计学意义( F = 1.715 9, P = 0.165;F = 0.185 8, P = 0.906;F = 0.081, P = 0.970;F = 0.523, P = 0.667)。术后整体满意度92%( 46/50),日常生活舒适度94%( 47/50),光晕发生率24%( 12/25),脱镜率98%( 49/50)。结论三焦点IOL可提供良好的全程视力,且患者主观满意度较高,术后视觉质量较好。 展开更多
关键词 三焦点 人工晶状体 视觉质量 离焦曲线 视敏度
在线阅读 下载PDF
多焦点人工晶体植入术后双眼离焦曲线对视觉功能的评价 预览
2
作者 凌宇 熊飞 +2 位作者 于璐 郝晓琳 程杰 《实用医学杂志》 CAS 北大核心 2019年第10期1635-1638,共4页
目的利用离焦曲线评价观察多焦点人工晶体植入术后患者的真实生活视力。方法回顾性分析2017年5月至2018年5月间收治的老年性白内障患者60例(120眼),按植入晶体不同分为两组,各30例(60眼)。其中植入ZEISSATLISA809M晶体者30例(60眼)设为... 目的利用离焦曲线评价观察多焦点人工晶体植入术后患者的真实生活视力。方法回顾性分析2017年5月至2018年5月间收治的老年性白内障患者60例(120眼),按植入晶体不同分为两组,各30例(60眼)。其中植入ZEISSATLISA809M晶体者30例(60眼)设为多焦非球面组(观察组),植入HOYA PY60AD晶体者30例(60眼)设为单焦非球面组(对照组),术后3个月观察术眼的屈光状态、双眼离焦曲线、脱镜率并问卷调查视觉质量。结果术前两组患者远视力及最佳矫正近视力情况差异无统计学意义(P > 0.05),术后观察组的裸眼近视力(U CNVA)明显优于对照组(P < 0.01);离焦曲线测量显示:观察组曲线下面积大于对照组,近距离曲线呈平滑趋势,而对照组的近距离曲线呈明显下降趋势,在-1.5 D(66 cm)、-3.5 D( 33 cm)两点处两组视力表现差异有统计学意义(P < 0.01)。结论两种晶体均可为患者提供良好的裸眼远视力;真实生活中多焦点非球面人工晶状体裸眼近视力效果更佳,脱镜率更高、视觉效果满意度更高,可为白内障患者术后提供更好的视觉质量。 展开更多
关键词 多焦点 人工晶体 离焦曲线
在线阅读 免费下载
散光矫正型多焦点人工晶状体植入术后临床效果
3
作者 肖雪冰 陈岩岩 +4 位作者 高明哲 栾多 崔秀英 刘亚南 刘洋 《中华眼视光学与视觉科学杂志》 CAS CSCD 2019年第4期265-269,共5页
目的:评价白内障超声乳化联合散光矫正型多焦点人工晶状体(MIOL)植入术后患者的长期临床效果。方法:前瞻性自身前后对照研究。选择在大庆油田总医院行白内障超声乳化联合散光矫正型多焦点IOL植入术患者50例(82眼),术后随访1年,分别观察... 目的:评价白内障超声乳化联合散光矫正型多焦点人工晶状体(MIOL)植入术后患者的长期临床效果。方法:前瞻性自身前后对照研究。选择在大庆油田总医院行白内障超声乳化联合散光矫正型多焦点IOL植入术患者50例(82眼),术后随访1年,分别观察术前,术后3个月、6个月、1年的裸眼远中近视力(LogMAR)、最佳矫正远中近视力(LogMAR)、离焦曲线、对比敏感度(CS)、全眼像差、预计残留散光和IOL轴位偏差分析及脱镜率。对手术前后各参数进行重复测量的方差分析,两两比较采用Bonferroni法及t检验。结果:散光矫正型MIOL植入术后,所有患者术后3个月、6个月、1年时远、中、近距离均可获得优于0.3的较好视力。术后3个月、6个月、1年时各距离视力较术前显著提高(远距离:F=26.39,P<0.001;中距离:F=13.68,P<0.001;近距离:F=12.90,P<0.001)。矫正远距离视力较裸眼视力略有提高,但差异无统计学意义,矫正前后近距离视力差异无统计学意义。术后6个月时,所有患者裸眼远视力接近0.0,且-4.0~+1.2D离焦下视力均可优于0.3LogMAR。术后1年时明视带眩光CS最好,明视、暗视的CS比明视眩光有所下降,暗视眩光分辨率最差,而在高频区(18c/d),CS随时间推移有显著提高,差异有统计学意义。术后1年全眼总散光(0.24±0.15)D,与术前[(1.56±0.38)D]相比,差异有统计学意义(t=3.31,P=0.023)。术后全眼总散光与术前预计残留散光[(0.15±0.07)D]接近,差异无统计学意义(t=2.31,P=0.102)。术后1年,IOL轴位平均偏离(3.12±1.51)°。术后脱镜率为100%。结论:散光矫正型MIOL能为白内障患者提供满意的全程视力、视觉质量和脱镜率,可预测性好,并有良好的旋转稳定性。 展开更多
关键词 散光矫正型多焦点人工晶状体 离焦曲线 对比敏感度 像差
双眼三焦点人工晶状体和双焦点人工晶状体植入术后早期视觉质量比较
4
作者 陈碧超 谭倩 +3 位作者 王潇 李雪婷 曹丹敏 王勇 《中华眼视光学与视觉科学杂志》 CAS CSCD 2019年第6期451-459,共9页
目的:对双眼植入三焦点人工晶状体(IOL)或双焦点IOL术后早期的视觉质量进行比较研究。方法:前瞻性临床研究。选择武汉爱尔眼科医院2017年4月至2018年5月收治的双眼单纯年龄相关性白内障患者52例(104眼),依据患者选择的IOL进行分组,双眼... 目的:对双眼植入三焦点人工晶状体(IOL)或双焦点IOL术后早期的视觉质量进行比较研究。方法:前瞻性临床研究。选择武汉爱尔眼科医院2017年4月至2018年5月收治的双眼单纯年龄相关性白内障患者52例(104眼),依据患者选择的IOL进行分组,双眼均植入双焦点IOL26例(52眼)作为双焦点组,双眼均植入三焦点IOL26例(52眼)患者作为三焦点组,术后随访3个月,观察2组间裸眼远视力(UDVA)、裸眼中视力(UIVA)、裸眼近视力(UNVA)、矫正远视力(BCDVA)、矫正远中视力(DCIVA)、矫正远近视力(DCNVA)、离焦曲线、对比敏感度、波前像差、调制传递函数等,并进行VF-14-CN生活质量问卷满意度及脱镜率调查。数据采用独立样本t检验、Mann-WhitneyU检验及χ^2检验进行统计分析。结果:三焦点组UIVA明显优于双焦点组(Z=-2.347,P=0.019),而2组间UDVA、UNVA、BCDVA、DCIVA、DCNVA差异均无统计学意义。三焦点组在-1.0、-3.0、-3.5、-4.0D离焦下视力明显优于双焦点组(Z=-2.619、-2.452、-2.452、-2.147,P=0.009、0.014、0.014、0.032)。2组间明视及明视眩光对比敏感度差异均无统计学意义。3、5mm瞳孔直径时,三焦点组眼内总高阶像差、眼内彗差、眼内三叶草差以及全眼总高阶像差、全眼三叶草差均明显低于双焦点组,差异均有统计学意义(P<0.05)。5mm瞳孔直径时,三焦点组眼内球差明显低于双焦点组(Z=-3.053,P=0.002),余指标组间差异无统计学意义。2组在3、5mm瞳孔直径时的调制传递函数差异均无统计学意义。2组间VF-14-CN得分、日常生活脱镜率以及患者满意度差异均无统计学意义。结论:与双眼植入双焦点IOL相比,双眼植入三焦点IOL能够为患者带来更好的中间距离视力,但二者在远近视力、视觉质量以及术后生活质量方面相近。 展开更多
关键词 三焦点人工晶状体 离焦曲线 对比敏感度 像差 视觉质量 生活质量
三焦点人工晶状体植入术后的早期临床效果 被引量:7
5
作者 肖雪冰 乌兰 +4 位作者 栾多 高明哲 罗杰 刘洋 方军 《中华眼视光学与视觉科学杂志》 CAS CSCD 2017年第5期311-314,共4页
目的评价白内障超声乳化联合三焦点人工晶状体(IOL)植入术后的早期临床效果。方法前瞻性自身前后对照研究。选择在大庆油田总医院行白内障超声乳化联合三焦点IOL植入术患者24例(26眼),术后随访3个月,分别观察术前,术后1周、1个月... 目的评价白内障超声乳化联合三焦点人工晶状体(IOL)植入术后的早期临床效果。方法前瞻性自身前后对照研究。选择在大庆油田总医院行白内障超声乳化联合三焦点IOL植入术患者24例(26眼),术后随访3个月,分别观察术前,术后1周、1个月、3个月的裸眼远视力、裸眼中距离视力和裸眼近视力,以及离焦曲线、对比敏感度(CS)和全眼像差。对手术前后各参数进行重复测量的方差分析。结果三焦点10L植入术后所有患者1周、1个月、3个月时远、中、近距离均可获得0-3LogMAR以上的较好视力。术后各距离视力较术前显著提高(P〈0.05)。术后3个月时裸眼远视力接近0LogMAR,且+1.5~-4.0D离焦下视力均优于0.3LogMAR:CS可见术后1周时明视眩光分辨率最好,明视、暗视的分辨率较明视眩光差,暗视眩光分辨率最差,差异有统计学意义(P〈0.05);术后l周、1个月、3个月时总像差、总低阶像差、离焦深度、散光均较术前明显降低,差异有统计学意义(P〈0.05)。结论三焦点10L提供了远、中、近兼顾的全程视力,术后视觉质量良好。 展开更多
关键词 三焦点人工晶状体 离焦曲线 对比敏感度 像差
Postoperative visual performance with a bifocal and trifocal diffractive intraocular lens during a 1-year follow-up
6
作者 Peter Mojzis Lucia Kukuckova +2 位作者 Katarina Majerova Peter Ziak David P.Pinero 《国际眼科杂志:英文版》 SCIE CAS 2017年第10期1528-1533,共6页
AIM:To evaluate and compare the clinical outcomes with a diffractive bifocal and trifocal intraocular lens(IOL) during a 12-month follow-up.METHODS:Prospective comparative study including 75 eyes of 38 patients(44-70 ... AIM:To evaluate and compare the clinical outcomes with a diffractive bifocal and trifocal intraocular lens(IOL) during a 12-month follow-up.METHODS:Prospective comparative study including 75 eyes of 38 patients(44-70 y) undergoing uneventful cataract surgery.Each patient was randomly assigned to one type of IOL,bifocal(35 eyes) or trifocal(40 eyes).Visual,refractive,and contrast sensitivity changes were evaluated in a 12-month follow-up.The binocular defocus curve was also measured at 12 mo postoperatively.RESULTS:No statistically significant differences between groups were found in postoperative uncorrected and corrected distance visual acuities(P≥0.276).Postoperative corrected near visual acuity(33 cm) was significantly better in the trifocal group during all follow-up(P≤0.004) as well as 6-month uncorrected near(P=0.008) and distancecorrected near visual acuities(P=0.016)(33/40 cm).Significantly better uncorrected intermediate and distance corrected-intermediate visual acuity were found during all follow-up in the trifocal group(P<0.001),which was consistent with differences among groups in binocular defocus curve.Differences among groups in contrast sensitivity were minimal,being only significant at 6 months for some low to medium spatial frequencies(P≤0.006).CONCLUSION:Bifocal and trifocal diffractive IOLs are able to provide an effective visual restoration which is maintained during a 12-month follow-up,with a clear benefit of the trifocal IOL for the intermediate vision. 展开更多
ReSTORSV25T0与ReSTOR SN6AD1多焦点人工晶状体植入术后临床疗效对比 预览 被引量:4
7
作者 朱俊英 王骞 +1 位作者 肖燕 陈鹏 《眼科新进展》 CAS 北大核心 2015年第10期955-957,964共4页
的对比观察ReSTORSV25TO与ReSTORSN6ADl多焦点人工晶状体(mohifocal intraocularlens,MIOL)植入术后的临床视觉效果。方法行白内障超声乳化吸出联合MIOL植入术的白内障患者41例(43眼),根据植入的MIOL不同分为两组:SN6ADl组20例... 的对比观察ReSTORSV25TO与ReSTORSN6ADl多焦点人工晶状体(mohifocal intraocularlens,MIOL)植入术后的临床视觉效果。方法行白内障超声乳化吸出联合MIOL植入术的白内障患者41例(43眼),根据植入的MIOL不同分为两组:SN6ADl组20例(22眼)植入ReSTORSN6ADlMIOL,SV25TO组21例(21眼)植入ReSTORSV25T0MIOL,观察两组患者术前及术后3个月裸眼近视力、裸眼中距离视力(50cm、70cm)及裸眼远视力,绘制离焦曲线,并进行对比敏感度检查、视觉质量及满意度问卷调查。结果术后3个月两组患者5in裸眼远视力对比差异无统计学意义(P〉0.05);SV25T0组患者50cm及70cm的裸眼中距离视力分别为(0.12±0.07)IogMAR和(0.17±0.08)logMAR,均明显优于SN6ADl组患者的(0.18±0.08)logMAR和(0.2±4-0.09)logMAR(均为P〈0.05),而SN6ADl组患者33om的裸眼近距离视力为(0.11±0.08)IogMAR,高于SV25TO组患者的(0.16±0.08)logMAR(P〈0.05);SV25TO组术后暗视下3.0c·d-1及6.0c·d-1空间频率的对比敏感度优于SN6AD1组,差异均有统计学意义(均为P〈0.05);术后问卷调查示两组患者均未出现明显视觉干扰,SV25T0组患者在近距离视力的视近满意度较SN6AD1组低,在中距离和远距离下满意度稍高,但是两组间差异均无统计学意义(均为P〉0.05)。结论ReSTORSV25TO与SN6AD1MIOL均能改善白内障患者术后视力及对比敏感度,ReSTORSV25T0在中距离视力的表现优于ReSTORSN6AD1。 展开更多
关键词 多焦点人工晶状体 白内障 离焦曲线 对比敏感度
在线阅读 下载PDF
Acrysof IQ Restor multifocal toric人工晶状体植入白内障患者的早期临床观察 预览 被引量:2
8
作者 陈祥菲 陆燕 +4 位作者 施宇华 薛春燕 陈银 杨丽萍 黄振平 《医学研究生学报》 CAS 北大核心 2014年第6期600-604,共5页
目的 Acrysof IQ Restor multifocal toric人工晶状体(intraocular len,IOL)是一种新型IOL,可在一次手术中实现老视和角膜散光的矫正。文章旨在评价白内障超声乳化联合Acrysof IQ Restor toric IOL植入术后患者的早期临床效果。方法... 目的 Acrysof IQ Restor multifocal toric人工晶状体(intraocular len,IOL)是一种新型IOL,可在一次手术中实现老视和角膜散光的矫正。文章旨在评价白内障超声乳化联合Acrysof IQ Restor toric IOL植入术后患者的早期临床效果。方法对前来南京军区南京总医院行白内障超声乳化联合多焦点散光型IOL植入患者7例(9眼)进行分析,其术前散光均≥1.0 D。术后随访3个月,分别观察术前及术后1周、1个月、3个月裸眼远近视力、最佳矫正远近视力、等效球镜等效球镜、焦点深度、预计残余散光、术后残余散光及人工晶状体的稳定性、对比敏感度(contrast sensitivity,CS)及脱镜率等。结果术后3个月,裸眼远视力(logMAR)为0.07±0.10,最佳矫正远视力为0.02±0.11,裸眼近视力为0.12±0.06,最佳矫正近视力为0.08±0.07,等效球镜≤±0.5D者8眼(88.9%),焦点深度为(5.32±1.78)D。术后3个月全眼总散光(0.25±0.28)D,与术前(1.55±0.39)D相比,差异有统计学意义(P〈0.05)。术后全眼总散光与术前预计残留散光(0.13±0.09)D接近,其差异无统计学意义(P〉0.05)。术后3个月,IOL轴位平均偏离(3.11±1.61)°。术后3个月与术后1个月相比,眩光和无眩光时CS在中低频区(3、6、12cpd)的提高差异无统计学意义(P〉0.05),而在高频区(18cpd)提高差异有统计学意义(P〈0.05)。术后脱镜率为100%。结论 Acrysof IQ Restor toric多焦点散光型人工晶状体能为白内障患者提供满意的全程视力、视觉质量和脱镜率,可预测性好,并有良好的旋转稳定性。 展开更多
关键词 多焦点散光型人工晶状体 离焦曲线 散光 对比敏感度
在线阅读 下载PDF
衍射型非球面双焦点人工晶状体植入术后综合视觉质量分析 预览
9
作者 冯骅 王慧娟 +1 位作者 秦虹 钟瑞生 《中国中医眼科杂志》 2018年第1期39-42,共4页
目的观察衍射型非球面双焦点(ZEISS AT LISE 809M)人工晶状体植入术后患者综合视觉质量。方法回顾性非随机研究。研究对象为2016年10月—2017年2月接受白内障超声乳化联合衍射型非球面双焦点人工晶状体(ZEISS 809)植入术的患者23例... 目的观察衍射型非球面双焦点(ZEISS AT LISE 809M)人工晶状体植入术后患者综合视觉质量。方法回顾性非随机研究。研究对象为2016年10月—2017年2月接受白内障超声乳化联合衍射型非球面双焦点人工晶状体(ZEISS 809)植入术的患者23例(34只眼),术后随访3个月。手术前后检查裸眼及矫正远、近视力,客观视觉质量分析系统(OQAS)测量调制传递函数截止频率(MTF cut off)、客观散射指数(OSI)、Strehl比值(SR),术后测定离焦曲线,并填写满意度及视觉干扰调查表,综合评价被观察眼的术后视觉质量。结果术后3个月最佳裸眼远视力(log MAR)0.04±0.08,优于术前(t=-12.499,P〈0.001),近视力(log MAR)0.21±0.12,优于术前(t=-17.772,P〈0.001)。术前被观察眼的MTF cut off为(14.15±9.56)c/deg,术后为(28.36±10.40)c/deg,优于术前(t=-7.094,P〈0.001)。术前OSI3.69±2.51,术后数值为2.70±1.64,优于术前(t=2.430,P=0.020)。术前SR 0.10±0.05,术后0.16±0.07,优于术前(t=-4.918,P〈0.001)。脱镜率88.24%。结论衍射型双焦点(ZEISS AT LISE 809M)人工晶状体植入术后视觉质量明显改善,且有较高脱镜率,但仍有视觉干扰。 展开更多
关键词 衍射型双焦点人工晶状体 离焦曲线 客观视觉质量分析
在线阅读 下载PDF
实时导航下+3.5 D非球面衍射型多焦点人工晶状体植入手术效果
10
作者 樊帆 刘馨 +1 位作者 方艳文 罗怡 《中华眼视光学与视觉科学杂志》 CAS CSCD 2017年第2期87-92,共6页
目的 评估在实时导航下新型+3.5 D非球面衍射型多焦点人工晶状体(IOL)植入术后视觉质量.方法 前瞻性临床研究.8例(12眼)白内障患者在Version实时导航下行超声乳化白内障吸除联合Diffractiva-aA多焦IOL (Diff-aA)植入术,术后3d、... 目的 评估在实时导航下新型+3.5 D非球面衍射型多焦点人工晶状体(IOL)植入术后视觉质量.方法 前瞻性临床研究.8例(12眼)白内障患者在Version实时导航下行超声乳化白内障吸除联合Diffractiva-aA多焦IOL (Diff-aA)植入术,术后3d、1个月、1年随访,评估项目包括裸眼及最佳矫正远近视力(LogMAR)、离焦曲线、撕囊口圆度(通过眼前节照相及Photoshop软件分析),IOL偏心值及倾斜度(Pentacam),以及患者满意度问卷调查.利用配对f检验、秩和检验、重复测量方差分析对手术前后数据改变进行统计分析.结果 术后3d裸眼远视力(UCDVA)为0.07(0.05~0.28),裸眼近视力(UCNVA)为0.38±0.13,均较术前UCDVA (0.51±0.25)及UCNVA (0.72±0.23)显著提高(P<0.01).术后1个月、1年UCDVA、UCNVA较术后3d有小幅提升,但差异无统计学意义.术后离焦曲线呈现双峰状态,第一峰在0(0~+0.5)D,代表患者接近正视,第二峰在-2.0(-2.4~-2.0)D,代表近工作距离在40~55 cm处.术后1个月撕囊口圆度平均为0.81±0.02,Diff-aA偏心值为(0.21±0.12)mm,倾斜度为1.11°±0.36°.术后1年视觉质量问卷显示7例(11眼)完全脱镜,无一例患者报告严重的视力困扰,3例(4眼)受到轻微或一般夜间光晕的影响.结论 在最新眼科手术导航系统的辅助下,植入新型+3.5 D多焦IOL能提供良好的全程视力. 展开更多
关键词 多焦人工晶状体 手术导航系统 离焦曲线 视觉质量