At present, in the workover operations of old gas wells in the Changqing Gas Field, due to years of exploitation in the production layer, pressure deficits, and general leakage during the well killing, the well must b...At present, in the workover operations of old gas wells in the Changqing Gas Field, due to years of exploitation in the production layer, pressure deficits, and general leakage during the well killing, the well must be plugged before the well can be killed. In particular, the fracture-cavity type fractures of the lower paleocarbonate reservoirs have serious leakage. Traditional plugging materials and traditional plugging materials and methods have some limitations in dealing with leakage problems. Therefore, a composite plugging system using polymer solution as the base carrier fluid, multi-particle size rigid particles, expandable particles and modified fibers is developed. Its formula is: water + 2% polyacrylamide + 0.1% N, N-methylene bisacrylamide polymer gel is the base carrier fluid;the formulation of the particle plugging agent was continuously optimized through the CDL-II high temperature and high pressure dynamic and static plugging ability to plug the core. The final formulation of the plugging agent is: 1) 20% rigid particles (5 mm, 1 mm, 0.5 mm CCP-3 ratio 4:2:1) + 1% 3 mm expanded particles SMK-1 + 1% 1 ~ 2 mm fiber SRXW-10;2) 20% rigid particles (3 mm, 0.1 mm, 0.05 mm CCP-3 ratio 3:2:1) + 1% 3 mm expanded particles SMK-1 + 1% 1 ~ 2 mm fiber SRXW-10. The water swelling multiples of the granular plugging agent in salt water are all above 7 times, which meets the requirements of leak-proof plugging operations under high salinity;3% HCl is selected as the gel breaker, and the plugging system has a gel breaking rate of 95%;through the water plugging and profile control experimental system, the sand-filled pipe is used to simulate the plugging effect under high temperature and high pressure, and the plugging system can be sealed for 5 days at a high temperature of 110°C and a high pressure of 20 MPa to achieve a good plugging of the formation. It is expected that the developed plugging system has a good application prospect in future workover operations.展开更多
Focused on the lost circulation control in deep naturally fractured reservoirs, the multiscale structure of fracture plugging zone is proposed based on the theory of granular matter mechanics, and the structural failu...Focused on the lost circulation control in deep naturally fractured reservoirs, the multiscale structure of fracture plugging zone is proposed based on the theory of granular matter mechanics, and the structural failure pattern of plugging zone is developed to reveal the plugging zone failure mechanisms in deep, high temperature, high pressure, and high in-situ stress environment. Based on the fracture plugging zone strength model, key performance parameters are determined for the optimal selection of loss control material(LCM). Laboratory fracture plugging experiments with new LCM are carried out to evaluate the effect of the key performance parameters of LCM on fracture plugging quality. LCM selection strategy for fractured reservoirs is developed. The results show that the force chain formed by LCMs determines the pressure stabilization of macro-scale fracture plugging zone. Friction failure and shear failure are the two major failure patterns of fracture plugging zone. The strength of force chain depends on the performance of micro-scale LCM, and the LCM key performance parameters include particle size distribution, fiber aspect ratio, friction coefficient, compressive strength, soluble ability and high temperature resistance. Results of lab experiments and field test show that lost circulation control quality can be effectively improved with the optimal material selection based on the extracted key performance parameters of LCMs.展开更多
Gas-solid fluidized bed separation is a highly efficient and clean technique for coal separation,and can effectively remove ash and sulfur contained gangue minerals from coal.However,the fine coal plugging distributor...Gas-solid fluidized bed separation is a highly efficient and clean technique for coal separation,and can effectively remove ash and sulfur contained gangue minerals from coal.However,the fine coal plugging distributor often leads to uneven fluidization and affects the separation effect.In this paper,different plugging ways were designed to study their effects on the fluidization characteristics and particle mixing.It was found that when the plugging phenomenon occurs,the minimum fluidization velocity of the fluidized bed gradually decreases as the plugging area enlarges.The difference between the top and the bottom of the bed minimum fluidization velocity increases accordingly,and a“stagnation phenomenon”occurs in the bed.The standard deviation of pressure fluctuations at the top of the bed is smaller than that at the bottom of the bed,which is the opposite of normal conditions.As the area of the plugging increases,the dead zone on the side wall of the fluidized bed significantly increases.The size of the dead zone is rapid reducing at the initial stage.It was noticed that the stratification of the low-density products is particularly affected by plugging,whereas the stratification of high-density products is not obviously influenced by certain conditions.展开更多
文摘At present, in the workover operations of old gas wells in the Changqing Gas Field, due to years of exploitation in the production layer, pressure deficits, and general leakage during the well killing, the well must be plugged before the well can be killed. In particular, the fracture-cavity type fractures of the lower paleocarbonate reservoirs have serious leakage. Traditional plugging materials and traditional plugging materials and methods have some limitations in dealing with leakage problems. Therefore, a composite plugging system using polymer solution as the base carrier fluid, multi-particle size rigid particles, expandable particles and modified fibers is developed. Its formula is: water + 2% polyacrylamide + 0.1% N, N-methylene bisacrylamide polymer gel is the base carrier fluid;the formulation of the particle plugging agent was continuously optimized through the CDL-II high temperature and high pressure dynamic and static plugging ability to plug the core. The final formulation of the plugging agent is: 1) 20% rigid particles (5 mm, 1 mm, 0.5 mm CCP-3 ratio 4:2:1) + 1% 3 mm expanded particles SMK-1 + 1% 1 ~ 2 mm fiber SRXW-10;2) 20% rigid particles (3 mm, 0.1 mm, 0.05 mm CCP-3 ratio 3:2:1) + 1% 3 mm expanded particles SMK-1 + 1% 1 ~ 2 mm fiber SRXW-10. The water swelling multiples of the granular plugging agent in salt water are all above 7 times, which meets the requirements of leak-proof plugging operations under high salinity;3% HCl is selected as the gel breaker, and the plugging system has a gel breaking rate of 95%;through the water plugging and profile control experimental system, the sand-filled pipe is used to simulate the plugging effect under high temperature and high pressure, and the plugging system can be sealed for 5 days at a high temperature of 110°C and a high pressure of 20 MPa to achieve a good plugging of the formation. It is expected that the developed plugging system has a good application prospect in future workover operations.
基金Supported by the National Natural Science Foundation of China(Grant No.51604236)Science and Technology Program of Sichuan Province(Grant No.2018JY0436)the Sichuan Province Youth Science and Technology Innovation Team Project(Grant No.2016TD0016)
文摘Focused on the lost circulation control in deep naturally fractured reservoirs, the multiscale structure of fracture plugging zone is proposed based on the theory of granular matter mechanics, and the structural failure pattern of plugging zone is developed to reveal the plugging zone failure mechanisms in deep, high temperature, high pressure, and high in-situ stress environment. Based on the fracture plugging zone strength model, key performance parameters are determined for the optimal selection of loss control material(LCM). Laboratory fracture plugging experiments with new LCM are carried out to evaluate the effect of the key performance parameters of LCM on fracture plugging quality. LCM selection strategy for fractured reservoirs is developed. The results show that the force chain formed by LCMs determines the pressure stabilization of macro-scale fracture plugging zone. Friction failure and shear failure are the two major failure patterns of fracture plugging zone. The strength of force chain depends on the performance of micro-scale LCM, and the LCM key performance parameters include particle size distribution, fiber aspect ratio, friction coefficient, compressive strength, soluble ability and high temperature resistance. Results of lab experiments and field test show that lost circulation control quality can be effectively improved with the optimal material selection based on the extracted key performance parameters of LCMs.
基金the National Natural Science Foundation of China-Xinjiang Joint Foundation(No.U1903132)National Natural Science Foundation of China(No.51904298).
文摘Gas-solid fluidized bed separation is a highly efficient and clean technique for coal separation,and can effectively remove ash and sulfur contained gangue minerals from coal.However,the fine coal plugging distributor often leads to uneven fluidization and affects the separation effect.In this paper,different plugging ways were designed to study their effects on the fluidization characteristics and particle mixing.It was found that when the plugging phenomenon occurs,the minimum fluidization velocity of the fluidized bed gradually decreases as the plugging area enlarges.The difference between the top and the bottom of the bed minimum fluidization velocity increases accordingly,and a“stagnation phenomenon”occurs in the bed.The standard deviation of pressure fluctuations at the top of the bed is smaller than that at the bottom of the bed,which is the opposite of normal conditions.As the area of the plugging increases,the dead zone on the side wall of the fluidized bed significantly increases.The size of the dead zone is rapid reducing at the initial stage.It was noticed that the stratification of the low-density products is particularly affected by plugging,whereas the stratification of high-density products is not obviously influenced by certain conditions.