期刊文献+
共找到14篇文章
< 1 >
每页显示 20 50 100
Synthesis of Ag and Cd nanoparticles by nanosecond-pulsed discharge in liquid nitrogen
1
作者 Mahmoud Trad Alexandre Nominé +4 位作者 Natalie Tarasenka Jaafar Ghanbaja Cédric Noel Malek Tabbal Thierry Belmonte 《化学科学与工程前沿:英文版》 EI CAS CSCD 2019年第2期360-368,共9页
The synthesis of CdO, Ag2O (5nm) and Ag (~20~30 nm) nano-objects is achieved simultaneously by nanosecond-pulsed discharges in liquid nitrogen between one cadmium electrode and one silver electrode. Oxidation occurs w... The synthesis of CdO, Ag2O (5nm) and Ag (~20~30 nm) nano-objects is achieved simultaneously by nanosecond-pulsed discharges in liquid nitrogen between one cadmium electrode and one silver electrode. Oxidation occurs when liquid nitrogen is fully evaporated and nanoparticles are in contact with the air. No alloy is formed, whatever the conditions, even though both elements are present simultaneously, as showed by timeresolved optical emission spectroscopy. This lack of reactivity between elements is attributed to the high pressure within the discharge that keeps each metallic vapor around the electrode it comes from. Each element exhibits a specific behavior. Cubic Cd particles, formed at 4 kV, get elongated with filamentary tips when the applied voltage reaches 7 and 10 kV. Cd wires are formed by assembly in liquid nitrogen of Cd nanoparticles driven by dipole assembly, and not by dielectrophoresis. On the contrary, silver spherical particles get assembled into 2D dendritic structures. The anisotropic growth of these structures is assumed to be due to the existence of pressure gradients. 展开更多
关键词 SPARK discharges SUBMERGED discharges timeresolved optical EMISSION SPECTROSCOPY liquid NITROGEN
Z扫描技术及其在非线性光学材料科学中的应用与进展 预览 被引量:5
2
作者 安辛友 吴卫东 +2 位作者 任维义 张志娇 汪建军 《西华师范大学学报:自然科学版》 2010年第4期 429-434,共6页
依据材料的非线性光学性质的研究为背景,介绍Z扫描技术的基本原理;分析影响Z扫描灵敏度的因素以及解决方法;对近年来激光Z扫描测量技术在试验和理论领域取得的研究进展予以论述并对Z扫描技术在材料科学研究领域的应用作出展望.
关键词 Z扫描技术 非线性光学性质 时间分辨
在线阅读 下载PDF
组合多量子阱的发光特性研究 预览
3
作者 于广辉 范希武 《光电子.激光》 EI CAS CSCD 1999年第3期 195-198,共4页
通过在77K时对ZnCdSe-ZnSe组合多量子阱结构的发光特性的测量,我们观测到了分别来自两组量子阱的激光发光,其跃迁能量与采用包络函数法计算的结果相符。由于两组量子阱之间注入效应的存在,使得两组量子阱在变密度激发... 通过在77K时对ZnCdSe-ZnSe组合多量子阱结构的发光特性的测量,我们观测到了分别来自两组量子阱的激光发光,其跃迁能量与采用包络函数法计算的结果相符。由于两组量子阱之间注入效应的存在,使得两组量子阱在变密度激发和时间分辨光谱中表现出不同的发光特性。 展开更多
关键词 组合多量子阱 时间分辨 荧光光谱 半导体激光器
在线阅读 下载PDF
人C-肽第1次国际标准品协作标定Ⅲa期研究
4
作者 于婷 曲守方 +1 位作者 黄杰 杨振 《药物分析杂志》 CSCD 北大核心 2017年第9期1721-1726,共6页
目的:评价人C-肽第1次国际候选标准品(批号13/146)的免疫反应性。方法:采用放射免疫法、酶联免疫法、化学发光免疫法和时间分辨免疫荧光法分析人C-肽第1次国际候选标准品(批号13/146)的效价。结果:本实验室测定人C-肽第1次国际... 目的:评价人C-肽第1次国际候选标准品(批号13/146)的免疫反应性。方法:采用放射免疫法、酶联免疫法、化学发光免疫法和时间分辨免疫荧光法分析人C-肽第1次国际候选标准品(批号13/146)的效价。结果:本实验室测定人C-肽第1次国际候选标准品(批号13/146)效价均值为9.98μg·安瓿-1(95%可信限为8.60~11.36),WHO报告中汇总均值为9.78μg·安瓿-1(95%可信限为9.31~10.25)。分别高出经WHO生物标准专家委员会审核通过的最终效价8.64μg·安瓿~(-1)(Ⅱ期研究中采用HPLC标定的结果)约15.5%和13.1%。试剂生产厂商应了解引入通过理化方法而非免疫学方法赋值的C-肽国际标准品(批号13/146)对其校准系统的潜在影响。结论:人C-肽第1次国际候选标准品(批号13/146)具有适宜的免疫活性,适合作为人C-肽免疫分析用国际标准品。 展开更多
关键词 胰腺细胞单链多肽 生物标志物 C-肽 国际标准品 标准物质标定 放射免疫法 酶联免疫法 化学发光免疫法 时间分辨免疫荧光法
神龙二号多脉冲电子束束参数的时间分辨测量技术 预览 被引量:1
5
作者 江孝国 王远 +9 位作者 杨国君 张卓 李洪 杨兴林 张小丁 李一丁 蒋薇 邓建军 石金水 李劲 《强激光与粒子束》 EI CAS CSCD 北大核心 2016年第8期173-177,共5页
神龙二号是一台三脉冲强流脉冲电子束直线感应加速器,就其多脉冲的电子束束参数的测量而言,基本要求是单个脉冲可分辨,进一步的要求是脉冲内时间可分辨。基于光学渡越辐射原理及瞬态发射度测量系统原理,发展了一种束斑与发散角可以分开... 神龙二号是一台三脉冲强流脉冲电子束直线感应加速器,就其多脉冲的电子束束参数的测量而言,基本要求是单个脉冲可分辨,进一步的要求是脉冲内时间可分辨。基于光学渡越辐射原理及瞬态发射度测量系统原理,发展了一种束斑与发散角可以分开测量的光学布局结构,结合多台高速分幅相机,成功研制了一套完整的多脉冲电子束束参数的测量系统,其特点是灵活的组合测量方式,全面满足了神龙二号复杂艰难的调试及参数测量工作要求。测量系统最高时间分辨测量能力达到约2ns的水平,单个脉冲可以获得至少8个时间分辨的束参数测量结果。 展开更多
关键词 神龙二号直线感应加速器 强流脉冲电子束 束参数 时间分辨测量 高速分幅相机
在线阅读 下载PDF
比较三种免疫分析法检测微囊藻毒素-LR 预览 被引量:1
6
作者 张艺 黄飚 +2 位作者 赵春城 钮伟民 金坚 《环境卫生学杂志》 2015年第5期479-482,共4页
目的评估微囊藻毒素-LR(MC-LR)的时间分辨荧光免疫分析(TRFIA)、纳米均相时间分辨荧光免疫分析(NH-TRFIA)和酶联免疫分析(ELISA)三种免疫检测方法。方法通过比较包被板、反应步骤、信号系统和试剂用量,分析反应条件的差异;通过... 目的评估微囊藻毒素-LR(MC-LR)的时间分辨荧光免疫分析(TRFIA)、纳米均相时间分辨荧光免疫分析(NH-TRFIA)和酶联免疫分析(ELISA)三种免疫检测方法。方法通过比较包被板、反应步骤、信号系统和试剂用量,分析反应条件的差异;通过分析灵敏度、精密度和准确性,比较上述方法的性能指标;通过检测实际样品,评估方法的可靠性。结果 NH-TRFIA反应时间最短,试剂消耗量最少,灵敏度最高,量程宽;TRFIA信号最强,稳定性佳;三种方法精密度高,相对标准差均小于15%。三种方法检测实际样品与高效液相色谱法的分析结果差异无统计学意义,认为可靠。结论 TRFIA和NH-TRFIA,技术优势明显,应用前景广阔。 展开更多
关键词 微囊藻毒素-LR 时间分辨荧光免疫分析 纳米均相时间分辨荧光免疫分析 酶联免疫
在线阅读 下载PDF
预览 被引量:2
7
作者 Jan Hansmann Paul Apfaltrer +5 位作者 Frank G Zoellner Thomas Henzler Mathias Meyer Gerald Weisser Stefan O Schoenberg Ulrike I Attenberger 《世界放射学杂志:英文版(电子版)》 2013年第5期202-207,共6页
AIM:To correlate dual-energy computed tomography(DECT) pulmonary angiography derived iodine maps with parameter maps of quantitative pulmonary perfusion magnetic resonance imaging(MRI).METHODS:Eighteen patients with ... AIM:To correlate dual-energy computed tomography(DECT) pulmonary angiography derived iodine maps with parameter maps of quantitative pulmonary perfusion magnetic resonance imaging(MRI).METHODS:Eighteen patients with pulmonary perfusion defects detected on DECT derived iodine maps were included in this prospective study and additionally underwent time-resolved contrast-enhanced pulmonary MRI [dynamic contrast enhanced(DCE)-MRI].DCE-MRI data were quantitatively analyzed using a pixel-by-pixel deconvolution analysis calculating regional pulmonary blood flow(PBF),pulmonary blood volume(PBV) and mean transit time(MTT) in visually normal lung parenchyma and perfusion defects.Perfusion parameterswere correlated to mean attenuation values of normal lung and perfusion defects on DECT iodine maps.Two readers rated the concordance of perfusion defects in a visual analysis using a 5-point Likert-scale(1 = no correlation,5 = excellent correlation).RESULTS:In visually normal pulmonary tissue mean DECT and MRI values were:22.6 ± 8.3 Hounsfield units(HU);PBF:58.8 ± 36.0 mL/100 mL per minute;PBV:16.6 ± 8.5 mL;MTT:17.1 ± 10.3 s.In areas with restricted perfusion mean DECT and MRI values were:4.0 ± 3.9 HU;PBF:10.3 ± 5.5 mL/100 mL per minute,PBV:5 ± 4 mL,MTT:21.6 ± 14.0 s.The differences between visually normal parenchyma and areas of restricted perfusion were statistically significant for PBF,PBV and DECT(P 【 0.0001).No linear correlation was found between MRI perfusion parameters and attenuation values of DECT iodine maps(PBF:r = 0.35,P = 0.15;PBV:r = 0.34,P = 0.16;MTT:r = 0.41,P = 0.08).Visual analysis revealed a moderate correlation between perfusion defects on DECT iodine maps and the parameter maps of DCE-MRI(mean score 3.6,k 0.45).CONCLUSION:There is a moderate visual but not statistically significant correlation between DECT iodine maps and perfusion parameter maps of DCE-MRI. 展开更多
关键词 DUAL-ENERGY COMPUTED tomography Timeresolved magnetic resonance imaging PULMONARY PERFUSION IODINE MAPS
在线阅读 免费下载
稀土标记轮状病毒抗体的研究 预览
8
作者 狄燕清 《商洛学院学报》 2012年第4期12-14,共3页
时间分辨荧光免疫分析技术是现代高灵敏度免疫研究的热点领域,适合于生命活性物质的痕量检测。以4,7-二氯磺酰基苯基-1,10-菲咯啉-2,9-二羧酸(BCPDA)作为双功能螯合剂与稀土铕离子标记人轮状病毒抗体RV(Ab),研究其最佳实验条件;根... 时间分辨荧光免疫分析技术是现代高灵敏度免疫研究的热点领域,适合于生命活性物质的痕量检测。以4,7-二氯磺酰基苯基-1,10-菲咯啉-2,9-二羧酸(BCPDA)作为双功能螯合剂与稀土铕离子标记人轮状病毒抗体RV(Ab),研究其最佳实验条件;根据解离增强原理,采用时间分辨荧光免疫分析技术对Eu3+-BCPDA-RV(Ab)的荧光寿命、荧光光谱等进行了测定。 展开更多
关键词 铕离子标记物 人轮状病毒 时间分辨荧光免疫分析
在线阅读 下载PDF
铕-吡哌酸时间分辨荧光法检测DNA含量 预览
9
作者 刘珍 孙思玲 +1 位作者 李锋 徐淑坤 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 2009年第6期 1599-1602,共4页
在pH值为7.2的Tris-HCl缓冲溶液中,铕与吡哌酸反应形成配合物。该体系中加入鲱鱼精DNA分子作用后荧光强度显著增强,并且在一定浓度范围内,DNA浓度与其荧光强度呈良好的线性关系,据此建立了一种简单的测定DNA的时间分辨荧光分析新方法。... 在pH值为7.2的Tris-HCl缓冲溶液中,铕与吡哌酸反应形成配合物。该体系中加入鲱鱼精DNA分子作用后荧光强度显著增强,并且在一定浓度范围内,DNA浓度与其荧光强度呈良好的线性关系,据此建立了一种简单的测定DNA的时间分辨荧光分析新方法。考查了体系的时间分辨荧光光谱,通过与普通荧光光谱的对比突显了采用时间分辨荧光法的优势,并对反应条件进行了优化。该方法对DNA的检测限为0.03 mg·L^-1(3σ),对浓度为4.0 mg·L^-1的DNA进行11次平行测定,其相对标准偏差为0.3%。DNA的浓度在0.1~6.0 mg·L^-1范围内与荧光强度呈良好的线性关系,线性方程为:ΔI=89.58c(mg·L^-1)+0.920 5,线性相关系数r=0.999 6。此方法已应用于合成样品中DNA的测定,结果和加标回收率令人满意。 展开更多
关键词 铕-吡哌酸 荧光探针 时间分辨荧光法 鲱鱼精DNA
在线阅读 下载PDF
NPB和5,6,11,12—四苯基四苯并在薄膜中的发光和能量传递 预览 被引量:1
10
作者 张步新 赵伟明 《量子电子学报》 CAS CSCD 2000年第4期 305-309,共5页
能量传递是发光材料中的重要现象。本文使用时间分辨光谱和发射光谱对NPB(二胺衍生物)掺Rubrene(5,6,11,12-四苯基四苯并)有机薄膜的能量传递过程进行了研究,建立了动力学方程,得到了与实验值相拟合的结论。... 能量传递是发光材料中的重要现象。本文使用时间分辨光谱和发射光谱对NPB(二胺衍生物)掺Rubrene(5,6,11,12-四苯基四苯并)有机薄膜的能量传递过程进行了研究,建立了动力学方程,得到了与实验值相拟合的结论。找到了产生白光的最佳掺杂比。然后制成带锁定层结构为ITO/CuPc/NPBl:Rubrene/TPBi/Alq/Mg:Ag薄膜电致发光器件,结果却得不到白光发射,说明能量传递过程在电场 展开更多
关键词 能量传递 NPB 薄膜 四苯基四苯
在线阅读 下载PDF
激光Z扫描测量技术 预览 被引量:1
11
作者 杨恢东 丁瑞钦 《激光技术》 EI CAS CSCD 北大核心 2000年第4期 195-202,共8页
激光Z扫描测量技术因装置简单、灵敏度高已成为材料光学非线性研究的一种重要手段,并随着其广泛应用而取得了较大的发展。作者采用分类综述的方法,对近年来泊光Z扫描测量在实验与理论领域取得的进展者了全面的论述与评价。
关键词 激光Z扫描测量 光学非线性 材料光学
在线阅读 下载PDF
电化学现场时间分辨电子自旋共振波谱 预览
12
作者 庄林 陆君涛 《电化学》 CAS CSCD 1996年第3期 250-253,共4页
在电子自旋共振对电化学暂态过程的研究中,人们通常将磁场固定在对研究信号敏感的位置,记录ESR强度随时间的变化。这种作法常导致大量的信息遗失,不但得不完整ESR谱线的变化,也很难分析多种磁物种共存的情况。
关键词 时间分辨 ESR波谱 现场电化学检测
在线阅读 下载PDF
荧光免疫分析中增强剂2—萘甲酰三氟丙酮的合成与分离提纯 预览 被引量:2
13
作者 王敏灿 常文保 《化学试剂》 CAS CSCD 北大核心 1995年第5期 287-288,共2页
在合成2-萘甲酰三氟丙酮的过程中对分离方法进行了改进,产率由45%提高到82%,且纯度高,可用作配制时间分辨荧光免疫分析的增强度。
关键词 萘甲酰三氟丙酮 荧光免疫分析法 TRFIA
在线阅读 下载PDF
时间分辨荧光免疫分析螯合剂BCPDA的合成 预览 被引量:2
14
作者 谢敏浩 罗世能 《化学试剂》 CAS CSCD 北大核心 1994年第6期 359-360,共2页
合成了新型时间分辨荧光免疫分析螯合剂-4,7-二氯磺基苯-1,10-菲咯啉-2,9-二羧酸(BCPDA)。产物的结构经红外光谱,核磁共振谱,元素分析确证。
关键词 BCPDA 合成 螯合剂 荧光免疫分析
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部 意见反馈